Product Number: 4200-4400-4800
The VELOX fire detection and alarm system, with its unique features reside at the apex of detection technology in the market. While the true intelligent analogue addressable detectors and devices connected to its loop, with its own decentralized intelligence; the VELOX panels gathers all the analogue values of these devices, and decide how to manage the alarm and ‘cause & effect’ of the entire installation.
The panel shall capture all the detectors and devices parameters such as, smoke obscuration, any faults reported by the detectors, temperature values, and process all these information against the programmed ‘cause & effect’ to decide how the action shall take place.
The VELOX fire detection and alarm system, with its unique features reside at the apex of detection technology in the market. While the true intelligent analogue addressable detectors and devices connected to its loop, with its own decentralized intelligence; the VELOX panels gathers all the analogue values of these devices, and decide how to manage the alarm and ‘cause & effect’ of the entire installation.
The panel shall capture all the detectors and devices parameters such as, smoke obscuration, any faults reported by the detectors, temperature values, and process all these information against the programmed ‘cause & effect’ to decide how the action shall take place.
|
|
|
|
Part No. |
4200 |
4400 |
4800 |
Number of Loops |
1 – 2. Expandable via individual |
1 – 4. Expandable via individual |
2 – 8. Expandable via individual |
Devices per loop |
240 |
||
Loop Current |
500mA |
||
On Board Sounder circuits |
2 x 1 Amp Programmable |
4 x 1 Amp Programmable |
8 x 1 Amp Programmable |
On Board Relays |
2 x 1 Amp 30v AC/DC Programmable |
4 x 1 Amp 30v AC/DC Programmable | |
Auxiliary Supply |
1 x 24v 500mA |
2 x 24v 500mA |
|
Open Collector / Logic Outputs |
8 x Programmable |
16 x Programmable |
|
On Board Power Supply |
4 Amp High Efficiency Switched Mode |
5 Amp High Efficiency Switched Mode |
2 x 5 Amp High Efficiency Switched Mode |
Mains Supply |
110 – 230 V AC (+10%, -15% tolerance) 50 / 60 Hz 1.9 Amp |
110 – 230 V AC (+10%, -15% tolerance) 50 / 60 Hz 1.7 Amp |
110 – 230 V AC (+10%, -15% tolerance) 50 / 60 Hz 2 Amp |
Charger Current |
2.0 Amp DDP monitored, temperature compensated integral charger |
2.2 Amp DDP monitored, temperature compensated integral charger |
2.2 Amp DDP monitored, temperature compensated integral charger |
Serial ports |
1 RS232 Onboard for PC, Modem or External Printer |
2 RS232 Onboard for PC, Modem or External Printer |
|
Metalwork Options |
Flushing Bezel, Ancillary Enclosure & Battery Box |
Semi Flushing Bezel |
|
Approvals |
BS EN 54 Part 2:1997 +A1 & AC and BS EN 54 Part 4:1998 +A1 & A2 , / KM 591678 |
||
Enclosure / Colour |
RAL 7016 / Anthracite Grey |
||
Networking |
Optional plug in Network card |
VELOX Life Safety – Canada
27 Terracon Place, Winnipeg, Manitoba, R2J 4B3, Canada
T: +1204 306 3930 | E: info@velox.ca
Linkedin – Twitter – Youtube – Instagram
VELOX Life Safety – Dubai
LIU-1 No.10 & 11 Dubai Silicon Oasis P.O. Box 293640 Dubai U.A.E
T: +971 (4) 3262730 F: +971 (4) 3262731
E: info@ateis.ae – Linkedin – Twitter – Youtube – Instagram